-- AT-G8032v2-MIB, Allied Telesis enterprise MIB: Ethernet Ring Protection Switching
--
-- Copyright (c) 2017 by Allied Telesis, Inc.
-- All rights reserved.
--
-- ============================================================================

    AT-G8032v2-MIB DEFINITIONS ::= BEGIN

        IMPORTS
            modules, DisplayStringUnsized
                FROM AT-SMI-MIB
            OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
                FROM SNMPv2-SMI
            TEXTUAL-CONVENTION, TruthValue
                FROM SNMPv2-TC;


        atG8032v2 MODULE-IDENTITY
            LAST-UPDATED "201702060000Z"
            ORGANIZATION
                "Allied Telesis, Inc"
            CONTACT-INFO
                "http://www.alliedtelesis.com"
            DESCRIPTION
                "G.8032v2 Ethernet Ring Protection Switching."
            REVISION "201702060000Z"
            DESCRIPTION
                "Defined system alarm trap."
            REVISION "201701170000Z"
            DESCRIPTION
                "Initial Revision of this MIB module."
            ::= { modules 604 }

-- The Allied Telesis G8032 module.


-------------------------------------------------------- --
-- G8032 Textual Conventions
-------------------------------------------------------- --

        AtG8032v2InstanceState ::= TEXTUAL-CONVENTION
            STATUS current
            DESCRIPTION
                "Defines the EPRS Instance states that are sent
                in G8032 State Notification Traps."
            SYNTAX INTEGER
                {
                unknown(1),
                init(2),
                idle(3),
                protection(4),
                manualSwitch(5),
                forcedSwitch(6),
                pending(7)
                }


-------------------------------------------------------- --
-- G8032 Notifications
-------------------------------------------------------- --

        atG8032v2Notifications OBJECT IDENTIFIER ::= { atG8032v2 0 }


        atG8032v2InstanceNotify NOTIFICATION-TYPE
            OBJECTS { atG8032v2NotificationInstanceName,
                      atG8032v2NotificationInstanceFromState,
                      atG8032v2NotificationInstanceCurrentState
                    }
            STATUS current
            DESCRIPTION
                "G8032 ERP Instance state transition notification."
            ::= { atG8032v2Notifications 1 }

        atG8032v2SystemAlarmNotify NOTIFICATION-TYPE
            OBJECTS { atG8032v2NotificationSystemAlarmState
                    }
            STATUS current
            DESCRIPTION
                "G8032 ERP system alarm transition notification.
                 Indicates whether any ERP instance is in a
                 state that is considered to be an alarm condition."
            ::= { atG8032v2Notifications 2 }


-- ---------------------------------------------------------- --
-- G8032 Notification Variables
-- ---------------------------------------------------------- --

        atG8032v2NotificationVariable OBJECT IDENTIFIER ::= { atG8032v2 1 }


        atG8032v2NotificationInstanceName OBJECT-TYPE
            SYNTAX DisplayStringUnsized (SIZE (1..32))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Assigned name of the G8032 ERP Instance."
            ::= { atG8032v2NotificationVariable 1 }


        atG8032v2NotificationInstanceFromState OBJECT-TYPE
            SYNTAX AtG8032v2InstanceState
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Defined state that a G8032 ERP instance is transitioning from."
            ::= { atG8032v2NotificationVariable 2 }


        atG8032v2NotificationInstanceCurrentState OBJECT-TYPE
            SYNTAX AtG8032v2InstanceState
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Defined current state that a G8032 ERP instance is transitioning to."
            ::= { atG8032v2NotificationVariable 3 }

        atG8032v2NotificationSystemAlarmState OBJECT-TYPE
            SYNTAX TruthValue
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Has value of 1 (true) if one or more G8032 ERP instance(s) are
                 in alarm state, else has value of 2 (false)."
            ::= { atG8032v2NotificationVariable 4 }


    END

--